The problem
The brief was a physical maze game for a public exhibition. The failure mode showed up in the first build: a nice object that people pushed a ball around while nothing happened. Scoring lived in someone's head, traps were painted lines, and the only feedback was other players laughing.
The design problem was not the maze. It was making the system notice events and answer them fast enough that players can follow what just happened. Score, timer, vibration, lights, audio, and a browser console were each a channel that could carry or muddy the same event.
The players were exhibition visitors, observed across 9 groups (36 people). A team member explained the rules before each round.
Three decisions
Nobody steers alone
Shared color wristbands are paired across players (A/B, B/C coupling), so no single person can drive any direction alone. One person alone gets immediate lock feedback, while paired touch drives all five synchronized channels.
- The conflict
- With one control per person, each visitor can play alone and nothing makes the group act together.
- What I gave up
- Buttons and a joystick, the first concept, were rejected as too much like an arcade game. Weight sensing or a five-finger pressure pad was considered but never tested.
- Evidence
- Putting on wristbands and finger sleeves took each group about a minute, and many players struggled with the rules even after a team member explained them.
A buzz on the finger instead of a shock, and one ball pass is one event
Relay-driven vibration motors in finger sleeves keep feedback on the body. Each IR sensor needs three consecutive samples and then cools down for 400 ms, so one ball pass is one round event.
- The conflict
- The electric-shock idea could not meet both complexity and safety, and a raw IR double-fire makes the score and the buzz on your finger disagree.
- What I gave up
- The mild electric shock trap from the initial concept, dropped at the Mid-Fi stage (25 Apr 2026). Vibration is a gentler sensation, and the cooldown introduces a brief blind window for rapid re-triggers.
- Evidence
- Raw IR reads could fire more than once on one ball pass, so score and buzz disagreed. Bench testing tuned debounce and cooldown until one ball pass produced exactly one game event.
The portfolio demo runs the exhibition's own rules
The JS Canvas console shares one event dispatcher. When USB Serial connects to the Arduino Mega it logs live traps and relays; without hardware attached it replays the same trap, score, and haptic state transitions in the browser.
- The conflict
- Exhibition wiring degrades without fast bench diagnostics, yet people reading a web portfolio never own an Arduino Mega harness.
- What I gave up
- Text-only serial logs plus a scripted video, which hide which of the 10 IR zones jittered and cannot prove trap timing. Two separate consoles for the exhibition laptop and the portfolio, which would drift apart. Live mode still needs desktop Chromium with USB permission.
- Evidence
- Parity tests caught drift whenever the firmware or the console was edited alone.
Try it yourself
Watch for the lock: tap one wristband alone and the maze refuses to move; switch to two-player co-touch and steer the orb to GOAL.
Built and tested
Everything hangs off a single round state machine. A ball breaks an IR beam, round state advances, and that one event fans out: score and timer displays update, a vibration pulse fires in the player's finger sleeve, the LED strip and speaker respond, and the browser console logs it.
Platform tilt runs on its own Uno (SafeTouchServoController) with hold-to-move behavior, the ball launcher's stepper on a second Uno, and the Mega handles sensing; all boards share one ground.
Exhibition photographs of the physical build alongside a video clip of the working feedback circuit.




What was tested
- Bench: debounce and cooldown tuned on the FC-51 IR array until one ball pass produced exactly one game event.
- Regression tests: serial sync, feedback sync, servo response, and audio parity, so the demo cannot quietly drift away from the firmware.
- Exhibition, June 2026: 9 groups (36 people) played. Some players were surprised by the vibration the first time. Play was observed, not instrumented.
Five states
| State | What happens | How it recovers |
|---|---|---|
| Normal | Score, timer, LED strip, sleeve haptics, audio cue, and the event log respond together on every validated event. | Debounce and cooldown keep one ball pass to one count; the servo holds only while contacts close. |
| Empty | Before Start, or one player touching a wristband alone: an idle or 'Co-touch required' cue instead of a silent tap. | Zero tilt on solo contact. |
| Offline | No Arduino Mega over USB: a Demo Mode banner, with all 5 channels still inspectable. | Parity tests keep Demo Mode on the firmware's event order and cooldown. |
| Error | USB unplugged, Web Serial unsupported, or a servo fault: the console logs the reason. | One step back to Demo Mode; a diagnostic IR zone helps bench pin checks. |
| Refused | Shock feedback, or a sensor bounce inside an active cooldown. | There is no shock hardware in the build, and one ball pass cannot charge two penalties. |
Results, limits and next steps
A working, exhibited system: firmware modules for game state, IR sensing, player chain input, vibration and audio; a Mega plus two Uno boards on a shared ground; and a browser console with parity tests.
The strongest lesson was that on hardware, timing is design. Debounce sounds like an electronics detail until a double-fire makes the score disagree with the buzz on your finger, and the player stops trusting the system. The weakest part is that I proved the loop works without measuring which parts of it mattered.
Limits
Exhibition play was observed, not instrumented. I can describe what players reacted to, but I cannot quantify which feedback channel carried the most information.
The build is a single exhibition unit, not a manufacturable product. Wiring is hand-run and calibration is per-venue, so nothing here proves durability, yield, or repeatable assembly.
Next
Log sensor events, feedback fires, and completion times per session, then compare rounds with channels selectively disabled, and cut the channels players ignore.
For interviewers
Process, research notes, rejected versions and hard questions. Collapsed by default.
How the work unfolded, stage by stage
Step-by-step trace of triggers, user expectations, system behavior, cognitive friction, and explicit recovery paths.
Facilitated sleeve fitting & shared wristband coupling
Observed in useUX & IASystems & HW- Trigger
- Four strangers gather around the wooden maze table at the public exhibition
- User mental model
- If each person gets a solo button, we'll play silently in parallel; shared wires make us figure out who needs to move together.
- System action
- A team member explains the rules and players put on the vibration finger sleeves; adjacent color wristbands (A/B, B/C) gate tilt axes so solo taps lock cleanly.
- Cognitive friction
- At the exhibition, gearing up took each group about a minute, and many players still struggled with the rules after the explanation.
- Edge & recovery
- If a single wristband taps alone, console & board immediately signal lock feedback so players discover co-touch rules without reading manuals.
Hold-to-move isolated servo actuation
Bench / hardware verifiedSystems & HWAI Trust- Trigger
- Coupled players bridge matching wristbands simultaneously
- User mental model
- When we let go, the board should stop immediately instead of violently slamming or freezing the round.
- System action
- SafeTouchServoController isolates tilt motors from the PlanB Mega feedback board and enforces hold-to-move bounds.
- Cognitive friction
- Running servo PWM on the same microcontroller as tight IR polling caused timing jitter and risked crashing the entire round.
- Edge & recovery
- Servo isolation allows mechanical fault resets without losing score, timer, or round state on the primary controller.
Debounced 10-zone FC-51 IR ball detection
Bench / hardware verifiedSystems & HWUX & IA- Trigger
- Rolling ball breaks an FC-51 infrared beam in trap, diagnostic, spare, or goal zone
- User mental model
- Hitting one trap should subtract once and buzz once—never trigger three penalties for one roll.
- System action
- Per-channel firmware debounce + cooldown gate compresses noisy IR bounce into exactly one atomic round event.
- Cognitive friction
- Raw sensor reads double- and triple-fired on a single ball pass, causing score and finger buzz to disagree and breaking player trust.
- Edge & recovery
- Bench tuning locked 1 ball pass = 1 event; cooldown duration trades a brief re-trigger blind window for absolute channel agreement.
Single round state machine fanning out to 5 channels
Observed in useSystems & HWUX & IA- Trigger
- Validated IR event advances the Mega round state machine
- User mental model
- The buzz on my finger, the sound, the lights, and the screen should feel like one unified physical consequence.
- System action
- One state transition simultaneously fires relay sleeve vibration, buzzer audio, LED strip shift, TM1637 display, and Web Serial log.
- Cognitive friction
- Exhibition play was observed across groups without per-channel telemetry logging, so exact channel contribution weights remain unmeasured.
- Edge & recovery
- Because every channel subscribes to one round state machine, subsystems can never contradict each other mid-game.
Live Web Serial console & parity-tested Demo Mode
Automated / synthetic gateSystems & HWAI Trust- Trigger
- Operator connects Mega over USB Web Serial or portfolio reviewer opens browser Demo Mode
- User mental model
- Without the wooden board on my desk, the browser console should honestly demonstrate the exact firmware rules—not a fake movie.
- System action
- JS Canvas console mirrors live Mega serial frames when attached and runs deterministic trap/sync simulation offline, guarded by parity tests.
- Cognitive friction
- Live Web Serial mode requires a desktop Chromium browser with USB permission, limiting mobile reviewers to Demo Mode.
- Edge & recovery
- Automated regression suite checks serial sync, feedback sync, servo response, and audio parity on every change.
Before and after
Consolidate unbuffered IR sensors & solo triggers into one debounced co-touch loop
Compare early failure modes against MazeRunners' SafeTouchServoController, sleeve haptics, and Web Serial state chain.
Wrist Co-Touch → Safe Servo → IR Debounce → 5-Channel Sync
Step through the physical closed loop aligning players' fingertips, the wooden board, and the Web Serial browser console.
Adjacent players must bridge matching color wristbands simultaneously before any axis tilts.
Physical feedback insights observed during exhibition rounds
Fired finger-sleeve vibration together with audio, LED strips and the score display from one round event.
Versions I threw away
Logged defects exposed during hardware bench checks, live debugging, and AI-draft reviews—plus the structural fixes that replaced them.
Mid-Fi Decision
2026-04Observed in useAI TrustUX & IA- Artifact before
- Mild electric shock trap concept delivered on wall contact
- Failure exposed
- Complexity and safety could not both be met (decision record, 25 Apr 2026).
- Fix applied
- Replaced shock hardware entirely with relay-driven vibration motors inside wearable finger sleeves.
Receipt: 02-bracelet-finger-sleeve.png + PlanB firmware haptic module
Bench Calibration & Console Sync
2026-05Bench / hardware verifiedSystems & HWAI Trust- Artifact before
- Uncalibrated raw FC-51 IR polling mixed on one microcontroller with servo PWM
- Failure exposed
- One ball pass could fire more than once, putting score and buzz out of sync.
- Fix applied
- Gave each sensor a three-sample debounce and a 400 ms cooldown feeding one Mega round state machine, put tilt on its own Uno (SafeTouchServoController), and wrote serial/feedback/servo/audio parity tests.
Receipt: 04-engineering-overview.png + firmware/web parity regression suite
Raw research notes
Verification boundary: Observed across 9 exhibition groups (36 players, ~3 completions) on the physical wooden maze, plus bench verification of 10-zone FC-51 IR debounce and Web Serial parity. Handwritten leaderboard scores were not archived.
Exhibition 4-Player Shared-Wristband Facilitation & Observation Guide
9 drop-in exhibition groups (4 strangers or peers per round, 36 players total) standing around the wooden maze table in a public gallery space.
Task Probe 01
Unverified hypothesis- Prompt
- Ask players to fit the wearable vibration finger sleeves before starting Round 1.
- What we watch for
- Physical dexterity hurdles, strap confusion, and whether sleeve fitting becomes a natural social icebreaker.
- Failure signal
- Loose finger sleeves sliding off mid-tilt, causing players to miss trap feedback entirely.
Task Probe 02
Unverified hypothesis- Prompt
- Watch the first 20 seconds when one player taps a wristband without their color partner.
- What we watch for
- How quickly players infer the shared-axis rule from immediate lock feedback without reading printed instructions.
- Failure signal
- Players repeatedly slamming the single contact assuming the wiring is broken.
Task Probe 03
Unverified hypothesis- Prompt
- Track where players look when the ball drops into an IR trap zone.
- What we watch for
- Whether players glance at the vertical scoring screen first or react immediately to wrist/finger vibration and board buzzer.
- Failure signal
- Scoreboard updates while physical feedback lags or misfires twice.
Planned debrief question: Did the shared wristband force you to coordinate differently with the person opposite you compared to normal party games?
Exhibition · Groups 1–9 (n=36)
Observed in use- Context
- Public exhibition in June 2026, nine rounds of four. A team member explained the rules before each round.
- Observation
- Each group took about a minute to put on the wristbands and finger sleeves. Attention went to the maze, the score and time display, the LEDs and the sounds. Some players were surprised by the finger-sleeve vibration the first time. Many still struggled with the rules even after the explanation; about 3 of 9 groups finished.
- Design & engineering change
- No change was made during the exhibition. The rule explanation before each round stayed part of the setup, and the struggle with the rules is recorded as a limit.
Hardware Bench · FC-51 Bounce
Bench / hardware verified- Context
- Rolling the ball past 10 infrared beam gates at varied speeds.
- Observation
- On raw reads, a single ball pass could fire more than once and charge more than one penalty.
- Design & engineering change
- Each sensor now needs three consecutive samples to trigger, followed by a 400 ms cooldown, so one physical pass is one serial event.
Mid-Fi Decision · 25 Apr 2026
Observed in use- Context
- Moving from the concept to the Mid-Fi build.
- Observation
- The electric-shock idea could not meet both complexity and safety.
- Design & engineering change
- Replaced it with vibration motors in wearable finger sleeves at the Mid-Fi stage.
Physical Table & 10-Zone IR Timing Spec
Board split, debounce thresholds, and five-channel round synchronization.
| Dimension | Locked Constraint | Rationale | Evidence |
|---|---|---|---|
| IR Debounce & Cooldown | 3 consecutive samples + 400 ms cooldown | Eliminates double/triple penalty firing when the ball wobbles over an FC-51 sensor rim. | Bench / hardware verified |
| Board Split | One Mega + two Uno (wristbands & servos; ball-launcher stepper), shared ground | Keeps servo and stepper code in their own sketches, apart from the Mega's sensing and scoring. | Bench / hardware verified |
| Solo-Tap Gate | Requires simultaneous pair conductivity per axis | No one can tilt an axis alone, so partners have to act together. | Observed in use |
| Dual-Mode Console Parity | Live Web Serial + browser Demo share identical reducer | Guarantees portfolio reviewers inspect the exact same round FSM rules seen at the gallery. | Bench / hardware verified |
Exhibition Experience Lead
- Priority
- Get four visitors playing together soon after they walk up to the table.
- Tension
- Complex multi-page rule placards go unread in loud gallery spaces.
- Resolution
- A team member explained the rules before each round. Many players still struggled with them, which stays an open problem.
Arduino & Wiring Builder
- Priority
- Keep 10 IR gates, servos, LEDs, buzzer, and Web Serial running continuously without brownouts or double triggers.
- Tension
- Sensing, wristbands, servos and the ball launcher are too much to keep in one sketch.
- Resolution
- Use one Mega plus two Uno boards on a shared ground, and give each IR sensor a three-sample debounce and a 400 ms cooldown.
Exhibition Visitor (Player)
- Priority
- Safe tactile thrill, fair penalty feedback, and zero awkwardness putting gear on.
- Tension
- The shock idea could not meet both complexity and safety; putting on wristbands and sleeves took each group about a minute.
- Resolution
- Replace the shock with finger-sleeve vibration, and fit the gear as part of the round setup.
What would I add first if running another exhibition?
Observed in usePersist timestamped round telemetry (completion rate, trap counts, group times) automatically in Web Serial CSV logs instead of relying on an unarchived whiteboard.
How would I fix the wearable sleeve friction?
Unverified hypothesisMove haptic actuators straight into the shared palm/wristband cuff itself so players never have to thread tiny finger sleeves.
Which hardware decision would I keep?
Observed in useSplitting the work across a Mega and two Uno boards on a shared ground, so the servo and stepper code stay out of the scoring sketch.
Why keep the browser demo mode synchronized with hardware firmware?
Bench / hardware verifiedPortfolio visitors cannot touch the wooden table; running the exact cooldown and pair-lock rules in the browser lets them inspect the design logic first-hand.
The hardware in 3D
Questions interviewers ask
Why did the trap become vibration instead of an electric shock?
I would explain that a public exhibition means unsupervised players of unknown age and health, so per-person consent and calibration were impossible; relay-driven vibration in finger sleeves kept the sensation on the body without the risk.
How did you make one ball pass produce one game event?
I would walk through debounce plus a cooldown window on each of the ten IR sensors, and why raw reads double-firing stopped score, timer, and haptics from agreeing with each other.
Why build a browser console for a physical build?
I would show the Web Serial console mirroring the maze live, plus a demo mode that runs without hardware, with regression tests keeping the two honest about firmware rules.
What does this prove that a screen-only case study does not?
I would say it proves I can carry an idea across the whole stack — sensing, firmware state machines, physical feedback, and a browser control surface — and make calibration and safety calls on hardware strangers will actually touch.
How others have challenged this design
Core thesis: Shared wristbands mean no player can steer alone. A three-sample IR debounce and a 400 ms cooldown keep one ball pass to one penalty.
Interrogates business framing, visual hierarchy, and whether deliberate friction actually earns its keep.
During the exhibition, 9 groups played, many still struggled with the rules after the explanation, and only about 3 groups finished—did the onboarding design actually work?
Empirical Defense
Only partly. A team member explained the rules before each round and gearing up took about a minute per group, yet many players still struggled with the rules. Attention went to the maze, the score and time display, the LEDs and the sounds, and some players were surprised by the vibration the first time. Rule onboarding stays an open problem.
Code & Hardware Receipt
Exhibition observation logs across 9 groups (36 players, ~3 completions) archived in /projects/maze#research-vault.
Unresolved Hypothesis (Honest Gap)
Handwritten leaderboard metrics were never digitized, and embedding vibration directly into the wristband cuff itself remains an untested v2 improvement.